獨特的消解技術,消除濁度影響,可適用于高濁度水樣;
采用電容式計量方式,樣品/試劑精度高,重復性好;
內置高效智能的數字化溫度控制系統(加熱溫度可調),保障溫度精確;
具有硬件自診斷報警、斷電保護、漏液檢測等多種設備狀態監測功能。
Unique digestion technology to eliminate the influence of turbidity, suitable for high turbidity water samples;
Adopting capacitive metering method, with high sample/reagent accuracy and good repeatability;
Built in efficient and intelligent digital temperature control system (adjustable heating temperature), ensuring accurate temperature;
Equipped with various equipment status monitoring functions such as hardware self-diagnosis alarm, power outage protection, and leakage detection
HQ-3600是基于國家標準分析方法的總氮在線自動監測儀,可適用于多種水體的總氮測量,內置質控功能,有利于遠程分析儀器狀態;儀器結構簡單、運維簡便,適合于長期無人值守的自動監測。
HQ-3600 is an online automatic monitoring instrument for total nitrogen based on Chinese national standard analysis method. It can be used for measuring total nitrogen in various water environment. With built-in quality control function, it is convenient to do remote analysis of monitor instrument status. The instrument has a simple structure and is easy for operation and maintenance. It is suitable for long-term unmanned automatic monitoring.
產品特點
1. 獨特的消解技術,消除濁度影響,可適用于高濁度水樣;
2. 采用電容式計量方式,樣品/試劑精度高,重復性好;
3. 內置高效智能的數字化溫度控制系統(加熱溫度可調),保障溫度精確;
4. 具有硬件自診斷報警、斷電保護、漏液檢測等多種設備狀態監測功能。
Product Features
1. Unique digestion technology to eliminate the influence of turbidity, suitable for high turbidity water samples;
2. Adopting capacitive metering method, with high sample/reagent accuracy and good repeatability;
3. Built in efficient and intelligent digital temperature control system (adjustable heating temperature), ensuring accurate temperature;
4. Equipped with various equipment status monitoring functions such as hardware self-diagnosis alarm, power outage protection, and leakage detection。
技術參數
測量參數 | 總氮 |
測量原理 | 過硫酸鉀消解紫外光度法 |
量程 | (0-2/10)mg/L,最大擴展量程為500 mg/L (量程可調,可根據客戶需要調整量程) |
線性 | R2≥0.995 |
穩定性 | 24h內不超過±10 % |
顯示 | 7寸LCD液晶顯示 |
環境溫度 | (5~40)℃ |
最大功率 | 100W,平均功率25W |
電源 | (85-264)V AC /(47-63)Hz,可擴展直流24V供電 |
外觀尺寸 | 約(W)400×(D)300×(H)640mm(不含突起物) |
串口通訊 | RS485 MODBUS |
模擬輸出 | (4-20)mA |
環境濕度 | ≤85%RH(無冷凝水) |
Measurement parameters | total nitrogen |
measuring principle | Potassium persulfate digestion ultraviolet spectrophotometry |
Range | (0-2/10)mg/L,The maximum extended range is 500 mg/L |
linear | R2≥0.995 |
stability | Not exceeding ± 10% within 24 hours |
display | 7-inch LCD display |
ambient temperature | (5~40)℃ |
maximum power | 100W,Average power25W |
power supply | (85-264)V AC /(47-63)Hz,Scalable DC 24V power supply |
Dimension | (W)400×(D)300×(H)640mm(Without protrusions) |
serial communication | RS485 MODBUS |
Analog Output | (4-20)mA |
ambient humidity | ≤85%RH(No condensed water) |
產品資料: